A welded end tank is tested on its own before it joins the core, so a leak does not contaminate a finished assembly. Fudiesel blanks the ports, pressurises the tank above the working boost and holds it under water, watching for a stream of bubbles rather than the single bubble a trapped pocket gives. The weld is then checked visually at the toe, since a leak often starts where the bead meets the parent metal rather than in the run itself. A tank that leaks is repaired only where the weld can be reworked and re tested, never filled with sealant. The test pressure and the hold time are recorded against the batch, and the same figure is used for every tank from that tool. Final specifications are subject to the written quotation or contract.