Categories

How is a hose inspected for pinholes?

Nov 6th,2026 20 Views

A pinhole is found by putting the hose under pressure and looking for a leak, because a hole small enough to pass a visual check will still let air through. The hose is capped at both ends, pressurised, and held under water, and the leak shows as a steady stream of bubbles rather than a single one. Position matters, since a pinhole often sits at a mould seam or at the point where the reinforcement was disturbed during forming. A hose that passes is marked and dried before packing, because water left inside a bag encourages a smell and a question from the buyer. A hose that fails is set aside rather than patched, since a patch on a thin wall is a future failure at a known point. Fudiesel leak tests hoses on the line and keeps the pass record with the batch. Final specifications are subject to the written quotation or contract.

Welcome to contact us
Email:fudiesel@fupower.com
WhatsApp: 8619901825634
Web :www.fudiesel.com